1. Mechanical action: High-speed agitation or strong mechanical shearing in solution can cause macromolecules to break. If the pam solution is stirred in a centrifugal pump for a few seconds, its molecular weight drops by 75%. If it is dissolved by high-speed stirring or transported by high-speed equipment, its molecular weight and flocculation performance will be significantly reduced.
2. Rust and iron compounds: Add a very small amount (such as 2mg / l) of iron compounds (such as fecl3), or a small amount of rust powder in the pam solution, stir it gently to disperse, the viscosity and flocculation performance of the pam solution will be greatly reduce. The pam solution was placed in a rusted iron, and the viscosity decreased by 78% after 4 hours, and the flocculation efficiency was greatly lowered.
3. The role of high temperature: pam macromolecule is very sensitive to high temperature, such as 0.1% pam solution at 80 ° C for 4 hours, the molecular weight decreased from 21 million to 7.6 million, placed at 50 ° C also dropped to 16.9 million; molecular weight is 1050 Million of pam, after 4 hours at 80 ° C, the molecular weight dropped to 3.3 million. For example, at 30 ° C, the molecular weight drops very slowly. If the original molecular weight of pam is very low, such as 3.7 million, there is little degradation by heat.
4. The effect of coexisting impurities: If there is suspended impurities in the pam solution, it will reduce its viscosity. Inorganic ions, especially high-valent ions, also have a large effect. For example, the viscosity of a pam solution is 191 centipoise. After adding nacl containing na+100 mg/l, the viscosity of the solution drops to 140, and after adding cacl2 containing ca2+100 mg/l, the viscosity drops to 30 cps.
5. Others: Ultraviolet irradiation will cause rapid degradation of pam. Strong irradiation for 4 hours will reduce the molecular weight of pam from 18 million to 10 million. The presence of oxidants in the solution will also accelerate degradation. The degradation of pam belongs to the free radical chain reaction. Any factor that can induce the generation of free radicals will accelerate the degradation of pam. The reaction of oxygen and iron can generate free radicals, and so is ultraviolet light, so be careful to avoid it. The performance of the pam solution is degraded, in part due to changes in the morphology of the macromolecule: from a long chain extending from a linear shape to a spherical shape shrinking and curling. The pam molecule contains a large number of negatively charged groups, which repel each other to make the macromolecules stretch. The molecules are long and fully exposed to active groups. They are good at bridging and bridging and have good flocculation performance. However, if there are more cations in the pam solution, they form an electric double layer around the negatively charged base of the macromolecule, which will weaken the repulsive force between the negatively charged groups and transform the pam macromolecule into a curled state. The higher the ion concentration, the greater the effect. Bivalent ions such as ca2+ are not only strongly adsorbed by negatively charged groups, but also may bridge the two negatively charged groups, which further enhances the crimping of macromolecules. This causes a decrease in the viscosity of the solution (the viscosity of the spherical macromolecule is much lower than that of the linear molecule), and also reduces the effective activity of the carboxyl group in the pam molecule, resulting in a significant decrease in flocculation performance.